OBSERVED CONDITION VIOLATION (X) ITEM
surface pond.
25. The producer is using a third
compartment of the milkhouse utensil
sink to prepare mastitis treatment
medicines.
26. The milkhouse wall has four 24 inch
square screen vents which open directly
into the breezeway. The doors on both
ends of the breezeway are closed.
27. The automatic stock watering tank has a
submerged inlet, however there is only an
approved vacuum breaker installed on
the main line of the community water
system which serves the farm.
28. A Nitrofuran derivative drug is found in
the dry cow cabinet. It has a complete
Extra Label.
29. Kopertox and Udderbalm are stored in
the hand wash sink.
30. The tanker driver is smoking in the
milkhouse while collecting the "Universal
Sample".
31. Drug administration equipment is being
stored in the handwash sink.